Noise Levels in 01507, MA | Find Quiet Neighborhoods With Our Sound Map
51 dBA
Average noise across 01507
Quiet office
2,242
Residents above the EPA 55 dBA threshold
17% of 01507 residents
88 dBA
Loudest residential point
Lawnmower at 1 m
This map shows modeled outdoor noise across 01507 at 100-meter resolution, combining road, aviation, and rail sources. Green areas measure below 45 dBA. Orange and red exceed the EPA's 55 dBA outdoor threshold linked to long-term health effects. Use the layer toggles to view each source on its own or all together.
Overall
Road
Rail
Aviation
Click the map to explore
35 dBa55 dBa (EPA limit)90+ dBa
3545557090
Quietest (dBA)Loudest
Colorblind friendlyoff
What the numbers sound like
30 dBAWhisper
40 dBASoft rainfall
45 dBAQuiet suburban street at night
50 dBAQuiet office
55 dBAEPA outdoor threshold: light traffic 100 ft away
60 dBANormal conversation an arm's length away
65 dBABusy restaurant
70 dBAHighway traffic 50 ft away
80 dBACity bus interior
Population Above the EPA Outdoor Threshold
The EPA's 55 dBA outdoor reference level is a common benchmark for residential noise exposure, especially for activity interference, annoyance, and long-term community noise concerns. About 2,242 01507 residents, or 17.1%, live above that level. By land area, 28.5% of 01507 is above 55 dBA.
Average noise levels for 01507 residents, grouped by direction from the center of 01507. Northern 01507 carries the highest population-weighted average; Southern 01507 carries the lowest. Just 6% of residents in Southern 01507 live in blocks above the EPA's 55 dBA threshold, a third of the share in Northern 01507.
Central 01507
49.9 dBA · Mostly quiet
Quiet office
8% of people above 55 dBA
QuietLoud
Eastern 01507
47.8 dBA · Mostly quiet
Quiet office
8% of people above 55 dBA
QuietLoud
Northern 01507
55.6 dBA · Moderate-loud
Quiet office to normal conversation
28% of people above 55 dBA
QuietLoud
Southern 01507
45.4 dBA · Mostly quiet
Quiet suburban street at night
6% of people above 55 dBA
QuietLoud
Western 01507
53.2 dBA · Moderate-loud
Quiet office to normal conversation
24% of people above 55 dBA
QuietLoud
Northern 01507 sounds about 103% louder than Southern 01507 to the human ear, a 10.2 dBA gap. Every 10 dBA roughly doubles perceived loudness. Within any of these directions, two homes a quarter mile apart can still differ by 10 or more dBA depending on how close they sit to a major highway.
How far back from Massachusetts Tpke do you need to be?
Massachusetts Tpke produces an estimated 78 dBA at its loudest centerline points. Noise drops logarithmically with distance, with the exact rate depending on what's between you and the road. Tree cover, walls, terrain, and pavement type all matter. At roughly a quarter mile back, traffic fades into the noise level of a soft rainfall.
At source
78 dBA
City bus interior
165 ft
63 dBA
Busy restaurant
330 ft
55 dBA
Quiet office to normal conversation
660 ft
46 dBA
Quiet office
¼ mile
37 dBA
Soft rainfall
½ mile
35 dBA
Soft rainfall
Calculated from the model's calibrated attenuation formula. About 68% of 01507 sits under tree canopy (much heavier than most zip codes) and roughly 4% is impervious surface like pavement and rooftops. Both are folded into the per-place decay rate above. Heavier canopy pulls noise down faster with distance; impervious surfaces slow the drop.
-->
Rail Noise
Active freight rail runs through parts of 01507. For most blocks the rail-only contribution is small. Combined road-plus-rail noise rarely exceeds road noise on its own. The exceptions are the handful of blocks within roughly a quarter mile of the right-of-way during pass-through hours.
Use the Rail toggle on the map above to isolate rail's contribution from road and aviation.
How Noise Is Distributed Across 01507
The bar chart below shows the share of 01507 residents in each noise band. About 79% of residents live below the EPA's 55 dBA threshold, and roughly 15% live in blocks above 60 dBA. Long-term exposure in that range is linked to elevated stress hormones and cardiovascular risk.
How 01507 Compares
01507 sits at the quieter end of the spectrum. Below: how 01507's average outdoor noise and share of residents above the EPA threshold compare with 01571, 01527, 01562, and 01550.
Average noise level (dBA)
01507's 50.8 dBA pop-weighted average is at the quieter end of the spectrum. Massachusetts as a whole averages 54.3 dBA and the U.S. averages 52.0 dBA. Both are lower than 01507 because most of either area is rural land away from major roads.
Share of residents above 55 dBA
About 17.1% of 01507 residents live in blocks where outdoor levels exceed the EPA's 55 dBA threshold. That's in the middle of its peer group. Measured by land area instead, 28.5% of 01507's footprint sits above 55 dBA, against a Massachusetts average of 40.0% and a national average of 28.1%.
What This Means if You're Moving to 01507
Distance from highways matters more than the neighborhood name. Two homes in the same zip code can differ by 20 dBA if one sits 100 meters from Massachusetts Tpke and the other 500 meters away. The model captures this at 100-meter resolution, so noise exposure changes block by block.
Tree canopy can help reduce modeled noise exposure. Roughly 68% of 01507 is under tree cover (much heavier than most zip codes), and the dominant land cover is deciduous forest. Both are measured from federal USDA Forest Service and USGS satellite imagery at 30-meter resolution. Streets with 60% or higher canopy show 3 to 5 dBA lower noise than comparable streets with bare ground or pavement, which is why the per-place decay rate above already accounts for it.
Sources & Methodology
The BestNeighborhood noise model is calibrated against nearly one million federal ground-truth measurements across four states. Road noise is computed from segment-level federal traffic data and propagated outward using physics-based acoustic decay, with attenuation rates that depend on the surrounding land cover.
All inputs are published federal datasets. Block-level noise is computed by combining road, rail, and aviation sound sources in the energy domain, the same physics used in professional environmental noise assessments. Read the full methodology.