Noise Levels in Muncy, PA | Find Quiet Neighborhoods With Our Sound Map

48 dBA
Average noise across Muncy
Quiet office
816
Residents above the EPA 55 dBA threshold
10% of Muncy residents
90 dBA
Loudest point in Muncy
Lawnmower at 1 m

This map shows modeled outdoor noise across Muncy at 100-meter resolution, combining road, aviation, and rail sources. Green areas measure below 45 dBA. Orange and red exceed the EPA's 55 dBA outdoor threshold linked to long-term health effects. Use the layer toggles to view each source on its own or all together.

Overall
Road
Rail
Aviation
Muncy, PA Map of Noise Levels in Muncy
Click the map to explore
35 45 55 EPA 70 90
Quietest (dBA) Loudest
Colorblind friendly off

What the numbers sound like

  • 30 dBAWhisper
  • 40 dBASoft rainfall
  • 45 dBAQuiet suburban street at night
  • 50 dBAQuiet office
  • 55 dBAEPA outdoor threshold: light traffic 100 ft away
  • 60 dBANormal conversation an arm's length away
  • 65 dBABusy restaurant
  • 70 dBAHighway traffic 50 ft away
  • 80 dBACity bus interior

Population Above the EPA Outdoor Threshold

The EPA's 55 dBA outdoor reference level is a common benchmark for residential noise exposure, especially for activity interference, annoyance, and long-term community noise concerns. About 816 Muncy residents, or 9.8%, live above that level. By land area, 13.6% of Muncy is above 55 dBA.

See how noise in Muncy compares to similar-sized cities.

Noise by Part of Muncy

Average noise levels for Muncy residents, grouped by direction from the center of Muncy. The highest population-weighted average is in northeastern Muncy; the lowest is in eastern Muncy, where just 5% of residents live in blocks above the EPA's 55 dBA threshold, about half the share in the loudest section.

Northeastern Muncy

60.5 dBA · Loud
Normal conversation an arm’s length away

11% of people above 55 dBA

QuietLoud

Northwestern Muncy

55.7 dBA · Moderate-loud
Quiet office to normal conversation

8% of people above 55 dBA

QuietLoud

Southeastern Muncy

48.7 dBA · Mostly quiet
Quiet office

5% of people above 55 dBA

QuietLoud

Southern Muncy

48.3 dBA · Mostly quiet
Quiet office

4% of people above 55 dBA

QuietLoud

Eastern Muncy

47.9 dBA · Mostly quiet
Quiet office

5% of people above 55 dBA

QuietLoud

To the human ear, noise in northeastern Muncy sounds about 139% louder than in eastern Muncy, a 12.6 dBA gap. Every 10 dBA roughly doubles perceived loudness. Within any of these directions, two homes a quarter mile apart can still differ by 10 or more dBA depending on how close they sit to a major highway.

Loudest Road Corridors

The model evaluates every road in Muncy using federal traffic counts, posted speeds, heavy-truck ratios, and pavement type. The source level shown is the modeled noise at the road centerline, where it is loudest. Noise drops with distance from there.

RoadTypeAvg. source dBAPeak source dBA
SR-0180 SH Interstate 71.2 75
Susquehanna Beltway Interstate 66.2 68
I-180 Interstate 66.2 68
Lycoming Mall Dr Principal arterial 60.4 64
SR-0405 SH Minor arterial 56.2 60

How far back from SR-0180 SH do you need to be?

SR-0180 SH produces an estimated 75 dBA at its loudest centerline points. Noise drops logarithmically with distance, with the exact rate depending on what's between you and the road. Tree cover, walls, terrain, and pavement type all matter. At roughly a quarter mile back, traffic fades into the noise level of a soft rainfall.

At source
75 dBA
City bus interior
165 ft
62 dBA
Busy restaurant
330 ft
54 dBA
Quiet office to normal conversation
660 ft
46 dBA
Quiet office
¼ mile
39 dBA
Soft rainfall
½ mile
35 dBA
Soft rainfall

Calculated from the model's distance-decay formula. Where federal land-cover data reaches, the decay rate is set from the place's tree canopy, pavement and land cover. The map above uses one standard rate everywhere.

Rail Noise

Rail lines run through or near parts of Muncy. The U.S. Department of Transportation's National Transportation Noise Map models their noise, and the figures on this page add it to road and aviation noise.

Use the Rail toggle on the map above to isolate rail's contribution from road and aviation.

How Noise Is Distributed Across Muncy

The bar chart below shows the share of Muncy residents in each noise band. About 89% of residents live below the EPA's 55 dBA threshold, and roughly 5% live in blocks above 60 dBA. A systematic review for the World Health Organization's 2018 Environmental Noise Guidelines found that the risk of ischemic heart disease rises about 8% for every 10 dB increase in long-term road traffic noise.

How Muncy Compares

Muncy sits at the quieter end of the spectrum. Below: how Muncy's average outdoor noise and share of residents above the EPA threshold compare with Montoursville, Milton, Montgomery, and Hughesville.

Average noise level (dBA)

Muncy's 48.1 dBA pop-weighted average is at the quieter end of the spectrum. Pennsylvania as a whole averages 52.9 dBA, and the U.S. averages 52.0 dBA.

Share of residents above 55 dBA

About 9.8% of Muncy residents live in blocks where outdoor levels exceed the EPA's 55 dBA threshold. That's in the middle of its peer group. Measured by land area instead, 13.6% of Muncy's footprint sits above 55 dBA, against a Pennsylvania average of 33.5% and a national average of 28.1%.

What This Means if You're Moving to Muncy

  • Distance from major roads matters more than the neighborhood name. Two homes in the same ZIP code can differ by more than 15 dBA when one sits 100 meters from a highway and the other 500 meters away. The model works at 100-meter resolution, so noise exposure changes block by block.
  • Land cover sets how fast noise fades in the model. About 26% of Muncy is under tree canopy, about average for cities, and about 15% is impervious surface such as pavement and rooftops. Its most common land cover is low-intensity developed land. These figures come from USDA Forest Service and USGS satellite data at 30-meter resolution, and the model uses them to set the rate at which noise fades with distance in Muncy.

Sources & Methodology

The BestNeighborhood noise model is calibrated against nearly one million federal ground-truth measurements across four states. Road noise is computed from segment-level federal traffic data and propagated outward using physics-based acoustic decay, with attenuation rates that depend on the surrounding land cover.

Federal datasets used:

FHWA Highway Performance Monitoring System: road geometry, traffic counts, lane configuration
U.S. DoT Bureau of Transportation Statistics National Transportation Noise Map: aviation and rail noise, road calibration ground truth
USGS / MRLC National Land Cover Database: land cover and impervious surface coverage
USDA Forest Service Tree Canopy Cover: vegetation density for sound propagation
U.S. Census Bureau TIGER/Line: block-level geography and population
U.S. EPA Levels Document: 55 dBA outdoor reference level

Health research cited:
World Health Organization Environmental Noise Guidelines systematic review (2018): road traffic noise and heart disease

All inputs are published federal datasets. Block-level noise is computed by combining road, rail, and aviation sound sources in the energy domain, the same physics used in professional environmental noise assessments. Read the full methodology.